Pre-requirement & reference
How to approach BMC on Advantech CIoT platforms
How to setup BMC IP address via BIOS
* Advantech’s IANA Enterprise Number used for OEM commands is 002839h
* IANA = Internet Assigned Number Authority
Purpose
Check or Set recent SMART FAN settings from system BMC
Target Audience
For all users of Advantech ICVG (CIoT) platforms and models' BMC FW is using Advantech legacy BMC code (Not 1BMC design), including FWA, SKY-7K, SKY-8K, SKY-9K Series.
Note1:
The commands in this FAQ are NOT suitable for The following models due to BMC design. Please find proper commands for there from our support portal.
- FWA-6520/5020/6510/6500 series
- SKY-7210/7221/8200 series
Note2:
Please DO NOT set FAN speed lower than LCR (lower critical. setting, ex 1200) value or it may trigger system events and BMC will force the speed to full on few systems.
How To
READ smart fan was activate or not , this command is also executable through IOL
#ipmitool raw 0x2c 0x16 0 0
00 ff 4e 01
–You will have 4 bytes returned value (e.g. 00 ff 4e 01)
–2nd byte = fan lv value (ff indicates that the reading may change dynamically because it is in Smart Fan mode. Please also check the last byte)
–Last byte
- 01 = smart fan Enabled
- 00 = smart fan Disabled = manual set
SET Fan Level* , this command is also executable through IOL
# ipmitool raw 0x2c 0x15 0x00 0x00 <FAN_LEVEL(unit:%) ,range 35~100(DEC), or 0x23~0xFF(HEX) >
Manually Enable SMART fan
# ipmitool raw 0x2c 0x15 0 0 0xff
* Manually set FAN LV will disable BMC Smart FAN function , it requires BMC reset or commands to get smart fan back