Purpose
Release NVM update package for NMC4007SR target version from 6.8/7.2/8.1/9.00 to 9.5
Target Audience
Everyone who needs to update NMC4007SR from 6.8/7.2/8.1/9.00 to 9.5
Minimum requirement
- The package in this FAQ supports upgrade from 6.8/7.2/8.1/9.00 to 9.5 only.
- Linux based OS
- i40e driver up to 2.15.9 or above (see driver requirement)
Steps
1. Download NMC4007SRNVM950.tgz from attachment
2. Check current nvm version from one of Ethernet device of NMC4007SR (b3dp0 as an example)
example 1: NVM 6.80
# ethtool -i b3dp0
driver: i40e
version: 2.23.17
firmware-version: 6.80 0x80003ce6 0.0.0
expansion-rom-version:
bus-info: 0000:3d:00.0
supports-statistics: yes
supports-test: yes
supports-eeprom-access: yes
supports-register-dump: yes
supports-priv-flags: yes
example 2: NVM 7.20
# ethtool -i b3dp0
driver: i40e
version: 2.23.17
firmware-version: 7.20 0x80007a01 0.0.0
expansion-rom-version:
bus-info: 0000:3d:00.0
supports-statistics: no
supports-test: no
supports-eeprom-access: yes
supports-register-dump: no
supports-priv-flags: yes
example 3: NVM 8.10
# ethtool -i b3dp0
driver: i40e
version: 2.23.17
firmware-version: 8.10 0x80009410 0.0.0
expansion-rom-version:
bus-info: 0000:3d:00.0
supports-statistics: yes
supports-test: yes
supports-eeprom-access: yes
supports-register-dump: yes
supports-priv-flags: yes
example 4: NVM 9.00
# ethtool -i b3dp0
driver: i40e
version: 2.23.17
firmware-version: 9.00 0x8000c8fa 0.0.0
expansion-rom-version:
bus-info: 0000:3d:00.0
supports-statistics: yes
supports-test: yes
supports-eeprom-access: yes
supports-register-dump: yes
supports-priv-flags: yes
3. Get in unzipped folder and run following command to execute update process. You should understand which device is available to be updated.
"-l nmc-4007sr.log" specifies the log file for recording output from the nvmupdate utility, if NMC can't success to update NVM file, please forward this log file to Advantech FAE (support@advantech-ncg.zendesk.com ),
# ./nvmupdate64e -l nmc-4007sr.log
Intel(R) Ethernet NVM Update Tool
NVMUpdate version 1.41.3.3
Copyright(C) 2013 - 2024 Intel Corporation.
WARNING: To avoid damage to your device, do not stop the update or reboot or power off the system during this update.
Inventory in progress. Please wait [****......]
Num Description Ver.(hex) DevId S:B Status
=== ================================== ============ ===== ====== ==============
01) Intel(R) I210 Gigabit Network N/A(N/A) 1533 00:001 Update not
Connection available
02) Intel(R) I210 Gigabit Network N/A(N/A) 1533 00:002 Update not
Connection available
03) Intel(R) Ethernet Controller X710 6.128(6.80) 1572 00:061 Update
for 10GbE SFP+ available
Options: Adapter Index List (comma-separated), [A]ll, e[X]it
Enter selection: 03 03 <-please key-in NMC-4007SR (X710) ID number
Would you like to back up the NVM images? [Y]es/[N]o: Y y <- suggest key-in y to backup old NVMUpdate in progress. This operation may take several minutes.
[****[ 230.361397] i40e 0000:3d:00.3: Reset Requested! (EMPR)
[ 230.365612] i40e 0000:3d:00.0: Reset Requested! (EMPR)
[ 230.385645] i40e 0000:3d:00.1: Reset Requested! (EMPR)
[ 230.405737] i40e 0000:3d:00.2: Reset Requested! (EMPR)
[ 230.665846] i40e 0000:3d:00.3: VF BW shares not restored
[ 230.901182] i40e 0000:3d:00.1: VF BW shares not restored
[ 231.134520] i40e 0000:3d:00.2: VF BW shares not restored
[ 231.338031] i40e 0000:3d:00.0: VF BW shares not restored ....******
Num Description Ver.(hex) DevId S:B Status
=== ================================== ============ ===== ====== ==============
01) Intel(R) I210 Gigabit Network N/A(N/A) 1533 00:001 Update not
Connection available
02) Intel(R) I210 Gigabit Network N/A(N/A) 1533 00:002 Update not
Connection available
03) Intel(R) Ethernet Controller X710 9.80(9.50) 1572 00:061 Update
for 10GbE SFP+ successful
A power cycle is required to complete the update process.
Tool execution completed with the following status: All operations completed successfully.
Press any key to exit.
- Wait few minutes for completing the upgrade process, you will find “All operations completed successfully” shown on screen after it completed, and follow the message to exit the utility.
- Power OFF and ON to apply the changes.
- Check nvm version from one of Ethernet device of NMC4007SR (b3dp0 as an example)
# ethtool -i b3dp0
driver: i40e
version: 2.23.17
firmware-version: 9.50 0x8000f12d 0.0.0
expansion-rom-version:
bus-info: 0000:3d:00.0
supports-statistics: yes
supports-test: yes
supports-eeprom-access: yes
supports-register-dump: yes
supports-priv-flags: yes
- Check VPD info from Advantech network device (Assume device NMC4007SR on bus 3d:00.0)
# lspci -s 3d:00.0 -vvv |grep -i "Vendor specific"
[V0] Vendor specific: N442
[V1] Vendor specific: V9.50
[V2] Vendor specific: V9.50.01
# lspci -s 3d:00.0 -vvv | head -n 4
3d:00.0 Ethernet controller: Intel Corporation Ethernet Controller X710 for 10GbE SFP+ (rev 02)
Subsystem: Advantech Co. Ltd Ethernet Controller X710 for 10GbE SFP+
Physical Slot: 11
Control: I/O- Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr+ Stepping- SERR+ FastB2B- DisINTx+
Check SVID: 13FE and SDID: 0027 with the command.
# ./nvmupdate64e -i -o
----------
<Instance vendor="8086" device="1572" subdevice="0027" subvendor="13FE" bus="61" dev="0" func="0" PBA="005700-000" port_id="Port 1 of 4" display="Intel(R) Ethernet Controller X710 for 10GbE SFP+">
<Module type="NVM" version="8000F12D" update="0">
</Module>
<Module type="RO" update="0">
</Module>
<VPD>
<VPDField type="String">NMC-4007</VPDField>
<VPDField type="Readable" key="MN">13FE</VPDField>
<VPDField type="Readable" key="V0">N442</VPDField>
<VPDField type="Readable" key="V1">V9.50</VPDField>
<VPDField type="Readable" key="V2">V9.50.01</VPDField>
</VPD>
<MACAddresses>
<MAC address="C400ADA487DC">
</MAC>
<SAN address="000000000200">
</SAN>
</MACAddresses>
</Instance>
<Instance vendor="8086" device="1572" subdevice="0000" subvendor="13FE" bus="61" dev="0" func="1" PBA="005700-000" port_id="Port 2 of 4" display="Intel(R) Ethernet Controller X710 for 10GbE SFP+">
<Module type="NVM" version="8000F12D" update="0">
</Module>
<Module type="RO" update="0">
</Module>
<VPD>
<VPDField type="String">NMC-4007</VPDField>
<VPDField type="Readable" key="MN">13FE</VPDField>
<VPDField type="Readable" key="V0">N442</VPDField>
<VPDField type="Readable" key="V1">V9.50</VPDField>
<VPDField type="Readable" key="V2">V9.50.01</VPDField>
</VPD>
<MACAddresses>
<MAC address="C400ADA487DD">
</MAC>
<SAN address="000000000201">
</SAN>
</MACAddresses>
</Instance>
<Instance vendor="8086" device="1572" subdevice="0000" subvendor="13FE" bus="61" dev="0" func="2" PBA="005700-000" port_id="Port 3 of 4" display="Intel(R) Ethernet Controller X710 for 10GbE SFP+">
<Module type="NVM" version="8000F12D" update="0">
</Module>
<Module type="RO" update="0">
</Module>
<VPD>
<VPDField type="String">NMC-4007</VPDField>
<VPDField type="Readable" key="MN">13FE</VPDField>
<VPDField type="Readable" key="V0">N442</VPDField>
<VPDField type="Readable" key="V1">V9.50</VPDField>
<VPDField type="Readable" key="V2">V9.50.01</VPDField>
</VPD>
<MACAddresses>
<MAC address="C400ADA487DE">
</MAC>
<SAN address="000000000202">
</SAN>
</MACAddresses>
</Instance>
<Instance vendor="8086" device="1572" subdevice="0000" subvendor="13FE" bus="61" dev="0" func="3" PBA="005700-000" port_id="Port 4 of 4" display="Intel(R) Ethernet Controller X710 for 10GbE SFP+">
<Module type="NVM" version="8000F12D" update="0">
</Module>
<Module type="RO" update="0">
</Module>
<VPD>
<VPDField type="String">NMC-4007</VPDField>
<VPDField type="Readable" key="MN">13FE</VPDField>
<VPDField type="Readable" key="V0">N442</VPDField>
<VPDField type="Readable" key="V1">V9.50</VPDField>
<VPDField type="Readable" key="V2">V9.50.01</VPDField>
</VPD>
<MACAddresses>
<MAC address="C400ADA487DF">
</MAC>
<SAN address="000000000203">
</SAN>
</MACAddresses>
</Instance>
</DeviceInventory>
Comments
0 comments
Please sign in to leave a comment.