Purpose:
This guide provides how to refresh the expired BIOS evaluation via Node Explorer.
Upgrade the nvram-xxx.img file again
Target Audience:
1. ICVG platforms that use Advantech BMC developed code
2. General for ICVG platform users
Steps:
- Please follow How to access node explorer to access Node Explorer
-
Go to the Maintenance --> Firmware Upgrade page
- Select the nvram xxx.img file to upload and start to upgrade.
4. Overwrite the nvram file with Force Upgrade
5. Click "Power Cycle" (don't remove power cord) and wait for more 5 minutes
6. Check the BIOS FW Version status from "Overview --> Firmware Versions"
Note 1: Please note that the power cycle is required for BIOS and FPGA upgrades.
Note 2: Please repeat the above instructions to upgrade the backup Firmware.