Purpose:
It lists FWA-3260 BMC PSU status detection for customer reference,
Target Audience:
For Advantech TSE, RBU AE, outsourcing service engineer(s) and End customer with the following knowledges :
- BMC troubleshooting experience
- System installation & troubleshooting experience
Content:
A. FWA-3260A (with LOM) contains Advantech code based BMC , the status of "PSU presence detected" may confuse customer due to the display.
Please use following table to check system's BMC version,
# ipmitool mc info
Device ID : 121
Device Revision : 1
Firmware Revision : 1.08
And refer following table to check PSU status from discrete readings
BMC 1.04 (or early version) & V1.10 New BMC was following this definition |
BMC 1.08 |
working PSU = discrete 0x0000 |
No PSU present in the system =discrete 0x0000 working PSU = discrete 0x0100 |
B. If the PSU status is not one of the above 3 values(ex: 0x0300), it means PSU module's self-test as fail, please contact Advantech RMA to exchange new PSU module ASAP.
# ipmitool sensor list | grep PSU
PSU1 | 0x0 | discrete | 0x0100| na | na | na | na | na | na
PSU2 | 0x0 | discrete | 0x0300| na | na | na | na | na | na
PSU-WATT | 45.000 | Watts | ok | na | na | na | na | na | na
C. If PSU1 & PSU2 are reporting 0x0100(BMC FW:1.10 or 0x0000 (BMC FW1.08)
PSU1 | 0x0 | discrete | 0x0100| na | na | na | na | na | na
PSU2 | 0x0 | discrete | 0x0100| na | na | na | na | na | na
It means FWA-3260 LOM CN4 didn't connected PSU's IPMB 4 PIN cable, please contact Advantech RMA to check PSU's IPMB cable connection,
Target Audience:
Everyone who uses this appliance
Minimum requirement:
- FWA-3260A (with LOM)