Phenomenon:
please look attached picture, when user sets eth_name item as blank in lbpcu.cfg.
Executing lbpcu utility will occur an Error message (Error : Invalid argument, Configuration not yet loaded.)
Analysis:
please check lbpcu version file, lbpcu V1.30 add a function "-d <eth_name>" , user can use "-d <eth_name>" to replace "<segment number>".
So, New lbpcu.cfg needs to define eth_name
LBPCU VERSION LIBLBPCU VERSION LBPCU PROTOCOL VERSION DATE FW_VERSION CHANGES / DESCRIPTION 01.30 01.26 00.08 05/13/2019 >= 1.20 - Add "-d <eth_name>" command, user can use "-d <eth_name>" to replace "<segment number>". This new command need new lbpcu.cfg format, please check lbpcu.cfg. - Add lbp_eth_name_to_seg_num(char *conf_file,char *eth_name, int *seg_number) API. |
Comments
0 comments