Purpose:
It lists PCIE-2232BP loading Advance LAN Bypass default setting command for customer reference,
Target Audience:
For Advantech TSE, RBU AE, outsourcing service engineer(s) and End customer with the following knowledges :
- Advanced LAN Bypass troubleshooting experience
Content:
- Please click following link , the PCIE-2232BP (Quad Port 10GBase-T Ethernet PCI Express Server Adapter with Intel® XL710) support Advance LAN bypass function, and this card's NIC ports are Copper type.
- The LAN chip of PCIE-2232 is a Intel® XL710, and Bypass configure rule needs to following XL710 setting to set as FIBER mode.
- To set the PCIE-2232BP LAN bypass rule as the default setting, please refer to the following table and enter the command "lbpcu -LoadDefault <segment> FIBER"
-
Set bypass as Load default # ./lbpcu -LoadDefault <segment> FIBER
Example:
A. Set PCIE-2232BP-00A1 segment 1 as load default
# ./lbpcu -LoadDefault 1 FIBER
B. Set PCIE-2232BP-00A1 segment 2 as load default
# ./lbpcu -LoadDefault 2 FIBER
Check Bypass setting # ./lbpcu -i <segment>
A. Check PCIE-2232BP-00A1 segment 1 setting
# ./lbpcu -i 1
A. Check PCIE-2232BP-00A1 segment 2 setting
# ./lbpcu -i 2