Purpose:
It provides NMC-6003 Firmware 16.35 for customer upgraded by themselves,
Target Audience:
For Advantech TSE, RBU AE, outsourcing service engineer(s) and End customer with the following knowledges :
- Mellanox Firmware troubleshooting experience
Content:
1. The NMC-6002FD firmware version 16.35 is available for download. However, to install the firmware, users need to download and install the Firmware Upgrade Utility (MST) from the NVIDIA website.,
https://network.nvidia.com/products/adapter-software/firmware-tools/
2. Please refer following table to upgrade NMC-6002FD Firmware 16.3.
item | command |
MST enabled |
# mst start Starting MST (Mellanox Software Tools) driver set Loading MST PCI module - Success Loading MST PCI configuration module - Success Create devices Unloading MST PCI module (unused) - Success |
FW 16.35 upgraded |
# flint -d /dev/mst/mt4119_pciconf0 -i fw-ConnectX5-rel-16_35_2000-Advantech_NMC-6002_2P_100G-UEFI-14.28.16-FlexBoot-3.6.805-20230324.bin -y burn
Current FW version on flash: 16.27.2008 New FW version: 16.35.2000
FSMST_INITIALIZE - OK Writing Boot image component - OK -I- To load new FW run mlxfwreset or reboot machine. |