Caution:
This article targets for FWA-6520 products which its BMC is AMI core based.
Purpose:
Users can refer to the SEL outputs to investigate the reboot behaviors that occurred on this machine.
Target Audience:
For users who are using Advantech FWA-6520 Series products.
Prerequisites:
1- Make sure the BMC can be approached through remote or local
2- Any external operation should be also included for SEL analysis (e.g. anyone pressed power button, or any commands to reset the system)
Procedures:
Reference SEL output from difference scenarios.
Press PWR BTN OFF --> ON
1 | 01/01/2005 | 00:02:51 | Power Unit PU_Status | Power off/down | Asserted
2 | 01/01/2005 | 00:02:59 | Power Unit PU_Status | Power off/down | Deasserted
3 | 01/01/2005 | 00:03:19 | System Event | Timestamp Clock Sync | Asserted
4 | 01/01/2005 | 00:03:19 | System Event SystemEvent | Timestamp Clock Sync | Asserted
5 | 09/06/2022 | 06:45:33 | System Event SystemEvent | Timestamp Clock Sync | Asserted
6 | 09/06/2022 | 06:45:33 | System Event | Timestamp Clock Sync | Asserted
Through IPMItool Over LAN (IOL) power OFF
1 | 03/05/2020 | 11:40:01 | Power Unit PU_Status | Power off/down | Asserted
Through IPMItool Over LAN (IOL) power ON
1 | 03/05/2020 | 11:40:01 | Power Unit PU_Status | Power off/down | Asserted
2 | 03/05/2020 | 11:40:14 | Power Unit PU_Status | Power off/down | Deasserted
Through IPMItool Over LAN (IOL) power CYCLE
1 | 09/11/2022 | 01:59:22 | Power Unit PU_Status | Power off/down | Asserted
2 | 09/11/2022 | 01:59:31 | Power Unit PU_Status | Power off/down | Deasserted
OS soft reboot "cmd = reboot"
# ipmitool sel elist
SEL has no entries
OS run "poweroff" command and then Press button to power ON
1 | 09/11/2022 | 01:59:22 | Power Unit PU_Status | Power off/down | Asserted
2 | 09/11/2022 | 01:59:31 | Power Unit PU_Status | Power off/down | Deasserted
Comments